Copper Paper Rectangular Conductor

BS 4653 Part 2 / 1970

INCREASE IN DIMENSIONS DUE TO THE COVERING

The dimensions of the conductor and the covered wire shall be determined by the method described in Appendix A.

The increase in dimensions due to the covering shall not exceed that specified nor shall it be less than that specified by more than the appropriate tolerance given in Table 5.

TOLERANCE ON COVERING

Increase due to the covering Increase due to the covering
Over Up to and including
mm mm %
0.25 0.5 10
0.5 1.25 7.5
1.25 5

PACKAGING

Unless otherwise specified the wire shall be wound on drums packed, wrapped and labelled in accordance with BS 2565†.

Get In Touch

We would love to hear from you! Please fill out this form and we will get in touch with you shortly.
  • This field is for validation purposes and should be left unchanged.

“Copyright © 2016 DuPont. All rights reserved. The DuPont Oval Logo, DuPont™, The miracles of science™ and all products denoted with ® or ™ are trademarks or registered trademarks of E. I. du Pont de Nemours and Company or its affiliates”

DISCLAIMER: The technical information contained herein is the result of extensive testing in the manufacturer’s laboratories. In addition any application advice given verbally, in writing or by testing corresponds to the best of our knowledge and belief. Since the use and application of any of our products lies beyond our area of control, it remains the responsibility of the user to verify the product’s suitability for their application.